STOPMODE=MANUAL, STARTMODE=MANUAL, COUNTMODE=ALWAYS
No Description
STARTMODE | Start Mode 0 (MANUAL): Counting starts as soon as ENABLE=1 1 (START_TRIGGER): Counting starts when the start-trigger event occurs |
STOPMODE | Stop Mode 0 (MANUAL): When writing a 1, stops the counter advancing 1 (STOP_TRIGGER): When stop trigger is active, stops the counter advancing 2 (COMPARE): When the count reaches the value programmed in EVENTCNTRCOMPARE, stops the counter advancing |
COUNTMODE | Count Mode 0 (ALWAYS): Increment on every clock cycle 1 (START_TRIGGER): Increment on every start-trigger event 2 (STOP_TRIGGER): Increment on every stop-trigger event 3 (ALL_TRIGGER): Increment on either every start- or stop-trigger event |